Technical parameters of high temperature water-cooled box unit

MODEL

KG-3W

KG-5W

KG-6W

KG-8W

KG-10W

KG-12W

KG-15W

Refrigerating capacity

KW

8.8

14.6

17.8

23.8

29

34.9

43.9

Kcal/h

7568

12556

15308

20468

24940

30014

37754

Rated power of the whole machine (KW)

2.8

4.3

5.05

7

8.5

10

13.45

Input  power supply

380V/3PH/50Hz

Whole machine current (A)

6

9

11

14

17

20

27

Compressor

Type

Fully enclosed vortex type

Rated power (KW)

2.25

3.75

4.5

3*2

3.75*2

4.5*2

3.75+7.5

Condenser

Type

High-efficiency shell tube type

Cooling water flow rate (m³ / h)

2

3.3

4

5.3

6.5

7.8

9.8

Evaporator

Type

The coil type

Flow rate of refrigerant (m³ / h)

1.5

2.5

3.1

4.1

5

6

7.6

Tank capacity (L)

50

50

50

150

150

150

150

Inlet and outlet of the water pipe diameter

DN25

DN25

DN25

DN40

DN40

DN40

DN50

Water pump

Rated power (KW)

0.55

0.55

0.55

1

1

1

2.2

Lift (m)

20

20

20

20

20

20

20

Refrigerant

Name

R22 / R134a / R407c

Filling capacity (Kg)

1.8

3

3.6

4.8

6

7.2

9

Control method

Expansion valve / capillary tube

Safety precautions

Compressor overheating protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence / phase deficiency protection, exhaust overheating protection, anti-freezing protection, water flow switch protection

Dimensions

Length (mm)

882

882

882

1404

1404

1404

1404

Width (mm)

524

524

524

694

694

694

694

Height (mm)

1250

1250

1250

1514

1514

1514

1514

Weight

Kg

130

150

150

300

430

735

735

 

Technical parameters of high temperature water-cooled box unit

MODEL

KG-20W

KG-25W

KG-30W

KG-40W

KG-50W

KG-60W

Refrigerating capacity

KW

61

72

91.5

122

144

174

Kcal/h

52460

61920

78690

104920

123840

149640

Rated power of the whole machine (KW)

17.2

20.2

25.5

34

40

49

Input  power supply

380V/3PH/50Hz

Whole machine current (A)

35

41

51

68

80

98

Compressor

Type

Fully enclosed vortex type

Rated power (KW)

7.5*2

9*2

7.5*3

7.5*4

9*4

11.25*4

Condenser

Type

High-efficiency shell tube type

Cooling water flow rate (m³ / h)

13.7

16.1

20.4

27.3

32.2

39

Evaporator

Type

High-efficiency shell tube type

Flow rate of refrigerant (m³ / h)

10.5

12.4

15.7

21

24.8

30

Tank capacity (L)

200

200

300

400

500

700

Inlet and outlet of the water pipe diameter

DN50

DN65

DN65

DN80

DN80

DN80

Water pump

Rated power (KW)

2.2

2.2

3

4

4

4

Lift (m)

20

20

20

20

20

20

Refrigerant

Name

R22 / R134a / R407c

Filling capacity (Kg)

12

15

18

24

30

36

Control method

Expansion valve / capillary tube

Safety precautions

Compressor overheating protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence / phase deficiency protection, exhaust overheating protection, anti-freezing protection, water flow switch protection

Dimensions

Length (mm)

1704

1704

2102

2305

2305

3004

Width (mm)

774

774

814

954

954

954

Height (mm)

1765

1765

1470

1875

1875

1874

Weight

Kg

820

900

1150

1200

1250

1300

Nominal cooling capacity: the inlet and outlet temperature of cooling water is 32℃ / 37℃, and the inlet and outlet temperature of carrying refrigerant is 12℃ / 7℃
The Company reserves the power to change the technology without notice of any change